When a stair flexes underfoot, the cause often traces back to the stringer. It carries the tread loads and transfers them, along with loads from the stair assembly, to the supporting structure at its connections.
Stringer choice also settles three things that surface later in the project: what the finished stair looks like from the side, how the treads attach, and how much of the stair can be completed in a shop rather than on site.
The stringer is the inclined beam that spans from floor to landing. Treads transfer load into it, the stringer carries that load in bending, and the connections at each end deliver it to the supporting structure.
Section depth is a major factor in stringer stiffness. A deeper section generally resists bending and deflection more effectively than a thicker but shallower one does, which is why the available depth — often limited by the soffit line or the stair opening — can constrain the design before material choice does.
A plate stringer is cut from flat, thick steel plate. The section depth is set by the plate width, so it can be sized to the span rather than to a rolled shape's catalog dimensions, and the face presents a single continuous surface with no flanges interrupting it.
That flat face is why plate stringers are common on exposed stairs. It takes paint or galvanizing evenly, hides tread connections behind it when the stringer is closed, and reads as a clean line from the side. SY Stairs uses plate stringers as the standard section on its modular assemblies.
Rolled C-channel has long been a common commercial stringer. The flanges place material away from the neutral axis, which contributes to bending stiffness for the section, and the channel's inside face can provide a convenient surface for tread carriers and clip angles.
Availability is the practical advantage: channel is a standard rolled shape, stocked in a range of depths. The visible flange edge along the stringer is the trade-off on exposed stairs, where it produces a heavier profile than plate.
A single member runs beneath the center of the flight and the treads cantilever out from it on both sides. With no stringers at the tread ends, the stair reads as floating treads, which is why it is often specified on feature stairs in lobbies and offices.
The structural demand is higher than the simple appearance suggests. A center member carries the full load alone and resists twist from anyone walking near a tread edge, so it needs sufficient depth, material, and engineering attention to torsion compared with a two-stringer stair of the same span.
Double stringers — one on each side of the treads — are a common arrangement for commercial and industrial stairs. Load is distributed between two members, tread ends are supported directly, and both stringers can also provide locations for handrail posts.
A center-beam stringer places a single beam under the treads with brackets carrying each tread. It is used mainly on industrial stairs where a narrow footprint matters more than the appearance of the tread ends.
A stair can satisfy every strength requirement in the code and still feel unpleasant to walk on. Perceived bounce is a vibration and serviceability issue, not simply a strength issue: it depends on the stair's natural frequency, stiffness, mass, and response to footfall, and a stair sized only for strength can still have noticeable vibration.
AISC Design Guide 34, Steel-Framed Stairway Design, provides guidance on stairway vibration and other serviceability considerations that engineers can use when a stair needs to feel solid underfoot.
Four things drive the outcome:
The practical step is to raise the question during design, not after erection. Ask the engineer of record which vibration criterion applies, and put it in the stair specification — retrofitting stiffness into an installed stair can mean adding a support, replacing the stringers, or accepting the existing feel.
A closed stringer runs as an unbroken line with the tread ends housed inside it, concealing the tread edges and the connections. An open or sawtooth stringer is cut into a stepped profile with the treads sitting on top, leaving the tread ends exposed and the stepped edge visible from the side.
How the treads attach matters to the build as much as the stringer profile. Treads carried on shop-welded clips or brackets can arrive as part of a finished assembly. Treads set and welded in place on site put that work into the field, along with the inspection that follows field welds.
Which tread sits on those connections is a separate decision with its own consequences for drainage, slip resistance, and install sequence. See steel stair tread types for that comparison.
On a concealed stair inside a rated shaft, the stringer is primarily a structural member. On an exposed stair — a lobby feature, an open office connector, an exterior stair tower — it is one of the largest visible elements of the assembly.
Plate presents a flat, uninterrupted face that suits an architectural line and takes a smooth painted finish. Channel shows its flange edge, which reads as an industrial detail rather than a defect but changes the profile noticeably at eye level.
Exposure also governs the finish. Hot-dip galvanizing is commonly specified for exterior stringers in a freeze-thaw and de-icing-salt climate, and it changes the surface appearance, which is worth confirming with the architect before specifying it on a stair that will be seen. For the exterior considerations in full, see our guide to exterior metal stairs for commercial buildings.
Whether those connections are made in a shop or on site is the larger method decision behind the stringer. See prefabricated vs. stick-built steel stairs.
Compare manufacturers for egress, decorative, and industrial stair applications in the Ohio Valley.
Advertiser Disclosure:
We receive compensation from some of the companies listed below.This compensation may affect which companies are included and the order in which they appear.
| Key standards |
OSHA, AISC, AWS, etc. |
|---|---|
| Typical lead time |
6 to 8 weeks |
| CAD data | Available |
| Key standards |
IBC, OSHA, etc. |
|---|---|
| Typical lead time |
8 to 12 weeks |
| CAD data | Available |
| Standards | OSHA,ADA, etc. |
|---|---|
| Lead time | Contact for details |
| CAD data | Contact for details |